用于供暖系统的数据中心余热回收利用技术
基金项目(Foundation):
邮箱(Email):
DOI: 10.20245/j.issn.1009-8402.2025.07.012
摘要:

随着互联网的日益普及,数据中心的规模呈现快速增长趋势,然而数据中心如此高的能耗显然与当前对能耗的要求不符,因此,如何降低数据中心的能耗成为了近年来人们所关注的话题,将数据中心余热回收用于供热系统成为降低数据中心能耗的重点研究方向。文章介绍了不同的用于供热系统的数据中心余热回收利用技术,并将各类技术进行了分析对比,阐述了各类用于供热系统的数据中心余热回收利用技术的研究进展,并进行了总结和展望,旨在帮助相关的研究人员更好的了解各类用于供热系统的数据中心余热回收利用技术,并促进各类技术的发展和应用。

Abstract:

As the Internet continues to gain widespread adoption, data centers are expanding at an accelerating pace. but the high energy consumption of the data center is obviously inconsistent with the requirements of the current dual control of energy consumption, so how to reduce the energy consumption of the data center has become a topic of concern in recent years, and the recovery of waste heat in the data center and used in the heating system has become the key research direction to reduce the data center energy consumption. This article introduces different data center waste heat recovery technologies for heating systems, and analyzes and compares them. This paper expounds the research progress of various data center waste heat recovery and utilization technologies for heating systems. and summarizes and looks forward to help relevant researchers better understand various kinds of data center waste heat recovery technologies for heating systems, and promote the development and application of related technologies.

参考文献

[1] 谢丽娜,李洁.数据中心余热回收技术与应用研究[J].中国电信业,2021,(S1):35-40.

[2] 林冬.“双碳”背景下我国绿色数据中心建设的思考与研究[J].节能,2023,42(4):73-76.

[3] 数据中心绿色低碳发展专项行动计划[J].安装,2024,(8):1-3.

[4] 戴新强,丁卫科,黄建如,等.数据中心空调系统能耗与节能应用研究[J].中国设备工程,2020(4):12-14.

[5] 胡进贤,周起如,谷国栋.数据中心能耗现状与节能方向的探索与研究[J].电脑编程技巧与维护,2019(4):93-95.

[6] KHOSROW E,GERARD F J,AMY S F.A review of data center cooling technology,operating conditions and the corresponding low-grade waste heat recovery opportunities[J].Renewable and Sustainable Energy Reviews.2014,31:622-638.

[7] 王硕,王海荣.双碳目标背景下中国数字经济健康发展的策略研究[J].当代经济管理,2022,44(8):11-16.

[8] 卢彬盛,何石泉,符军.数据中心余热利用现状及其跨季储热前景分析[J].节能,2023,42(8):88-92.

[9] 中国电子技术标准化研究院.中国数据中心能效研究报告[M].北京:中国电子技术标准化研究院,2015:1-4.

[10] LUO Y,ANDRESEN J,CLARKE H,et al.A ‘system’ integration for energy recovery within data centres using combined cooling and power technology[J].Procedia Manufacturing,2018,21:710-716.

[11] 中国电子工程设计院.数据中心设计规范:GB 50174—2017[S].北京:中国计划出版社,2017.

[12] 红高.最高级的供热方式:利用电脑余热[J].环境,2011(4):50-52.

[13] 张飞,贺晓,程序,等.数据中心余热回收系统应用研究[J].邮电设计技术,2022,(12):80-83.

[14] 王红霞,白仁宇,陈红兵,等.数据中心余热回收技术及供暖应用[J].节能与环保,2024(12):54-62.

[15] 张宪,王志刚,蒋凯.关于数据中心余热回收利用及余热供热智能控制的研究[J].电信工程技术与标准化,2024,37(S1):203-207.

[16] 李国柱,崔美华,黄凯良,等.数据中心余热利用现状及在建筑供暖中的应用[J].科学技术与工程,2022,22(26):11287-11295.

[17] MATTEO B,FEDERICO S,GUIDO Z,et.Modelling a fifth-generation bidirectional low temperature district heating and cooling (5GDHC) network for nearly Zero Energy District (nZED)[J].Energy Reports,2021(prepublish).

[18] WAHLROOS M,P?RSSINEN M,RINNE S,et al.Future views on waste heat utilization -Case of data centers in Northern Europe [J].Renewable & Sustainable Energy Reviews,2018,82:1749-64.

[19] OR′O E,ALLEPUZ R,MARTORELL I,et al.Design and economic analysis of liquid cooled data centers for waste heat recovery:a case study for an indoor swimming pool[J].Sustainable Cities and Society,2018,36:185-203.

[20] 肖彪,常华伟,赵树男,等.一种基于空气源热泵的数据中心能量回收系统研究[J].可再生能源,2022,40(4):475-480.

[21] DAVIES G F,MAIDMENT G G,TOZER R M.Using data centres for combined heating and cooling:an investig-ation for London[J].Applied Thermal Engineering,2016,94:296-304.

[22] HUANG Q H,SHAO S Q,ZHANG H N,et al.Development and composition of a data center heat recovery system and evaluation of annual operation performance[J].Energy,2019,189.DOI:10.1016/j.energy.2019.116200.

[23] DING J,ZHANG H N,LENG D M,et al.Experimental investigation and application analysis on an integrated system of free cooling and heat recovery for data centers[J].International Journal of Refrigeration,2022,136:142-151.

[24] 黄翔,史东旭,褚俊杰,等.藏区数据中心蒸发冷却与余热回收系统应用探讨[J].暖通空调,2023,53(3):103-109,116.

[25] 崔科,赵进良,付晓飞.数据中心空调冷却及余热回收系统技术分析[J].节能技术,2020,38(4):379-384.

[26] 张炳华,郭震,王舜,等.基于间接蒸发冷却系统形式的数据中心余热回收利用技术[J].暖通空调,2025,55(2):120-125.

[27] 杨洁婷.数据中心制冷及余热回收系统节能优化控制[D].北京:北京建筑大学,2023.

[28] JANG Y,LEE D,KIM J,et al.Performance chara-cteristics of a waste-heat recovery water-source heat pump system designed for data centers and residential area in the heating dominated region[J].Journal of Building Engineering,2022,62.DOI:10.1016/j.jobe.2022.105416.

[29] 孙永霞,刘琴.数据机房余热回收的相关研究[J].建筑热能通风空调,2022,41(4):71-73.

[30] 崔科,马长明,檀志恒,等.数据中心余热在城镇供热中的应用研究[J].建筑节能(中英文),2023,51(7):74-78.

[31] 周峰,宋宇,马国远,等.面向小型数据中心余热供暖的水源热泵系统负荷特性分析[J].制冷学报:1-12.

[32] MISKIC J,DOROTIC H,PUKSEC T,et al.Optimization of data centre waste heat integration into the low-temperature district heating networks[J].Optimization and Engineering,2024,25(1):63-91.

[33] YIN P,GUO Y,ZHANG M,et al.Performance analysis of lake water cooling coupled with a waste heat recovery system in the data center[J].Sustainability.2024,16(15).DOI:10.3390/su16156542.

[34] HUANG P,COPERTARO B,ZHANG X,et al.A review of data centers as prosumers in district energy systems:renewable energy integration and waste heat reuse for district heating[J].Applied Energy,2020,258.DOI:10.1016/j.apenergy.2019.114109.

[35] FEIKE F,OLTMANNS J,DAMMEL F,et al.Evaluation of the waste heat utilization from a hot-water-cooled high performance computer via a heat pump[J].Energy Reports.2021,7(s4):70-78.

[36] MURPHY A R,FUNG A S.Techno-economic study of an energy sharing network comprised of a data centre and multi-unit residential buildings for cold climate[J].Energy and Buildings,2019,186:261-275.

[37] LI J,YANG Z,LI H L,et al.Optimal schemes and benefits of recovering waste heat from data center for district heating by CO2 transcritical heat pumps[J].Energy Conversion and Management.2021,245.DOI:10.1016/j.enconman.2021.114591.

[38] REINERS T,GROSS M,ALTIERI L,et al.Heat pump efficiency in fifth generation ultra-low temperature district heating networks using a wastewater heat source[J].Energy.2021,236.DOI:10.1016/j.energy.2021.121318.

[39] 黄德才.湖水源数据中心余热回收系统仿真模拟研究[D].湖南大学,2022.

[40] ADAMSKI J,GóRZENSKI R,KARGIN T C,et al.Planning data center waste heat re-use in a university campus-a case study and software tools;proceedings of the 14th ACM International Conference on Future Energy Systems (e-Energy),Orlando,FL,F Jun 20-23,2023[C].2023.DOI:10.1145/3599733.3600256.

[41] BUFFA S,COZZINI M,D′ANTONI M,et al.5th generation district heating andcooling systems:A review of existing cases in Europe[J].Renewable and Sustainable Energy Reviews,2019,104:504-522.

[42] 白银.数据驱动的低温区域供热系统温度预测与控制研究[D].天津:天津理工大学,2020.

基本信息:

DOI:10.20245/j.issn.1009-8402.2025.07.012

中图分类号:TP308;TK115;TU832

引用信息:

[1]李朝帅,马国远,宫悦轩.用于供暖系统的数据中心余热回收利用技术[J].制冷与空调,2025,25(07):79-90.DOI:10.20245/j.issn.1009-8402.2025.07.012.

发布时间:

2025-07-28

出版时间:

2025-07-28

检 索 高级检索

引用

GB/T 7714-2015 格式引文
MLA格式引文
APA格式引文